Looking for your apps? Click the account icon in the upper right corner of the page.

Ambient conditions

Ambient Temperature:
+41 °F to +104 °F (+5 °C to +40 °C)
Extended operating temperature of the scanner:
+14 °F to +131 °F (-10 °C to +55 °C)
Low temperature operation: the scanner must be powered on while internal temperature is at or above +59 °F (+15 °C)
High temperature operation*: additional accessory thermal cover required, further information on request.
Storage:
+14 °F to +140 °F (-10 °C to +60 °C)
Environment:
Indoor and temporarily outdoor use, pollution degree 2
Humidity:
Non-condensing
Altitude:
< 6561 ft (2000 m)
IP rating of the scanner when in an upright position:
IP54
*For extended operation at 131 °F (55 °C ): Cool down the accessory thermal cover to 5 °F (-15 °C) or colder and store the scanner below 77 °F (25 °C). Prepare scanner with thermal cover and without any other accessory. Turn it on. Scanning is possible for 1 hour. Then turn the scanner off to cool it down to below 77 °F (25 °C) for 2 hours before scanning again with a cooled thermal cover.