We recommend that you check your Topcon scanner at least once a month. This allows you to spot trouble before it starts, and provides you with an efficient measuring system.
The CR-P1 L, CR-P1 M and CR-P1 S are precision instruments that contains many sensitive components, and thus must be handled with care. Follow these procedures to prevent problems:
- Check the cables for damage to outside insulation, connectors, and pins.
- Check the housing of the scanner for damage.
- Check the housing and the connectors of the battery for damage.
- Place a dust cover over the scanner, when not in use.
- Do not lubricate the CR-P1 L, CR-P1 M and CR-P1 S.
- Clean the mirror if it becomes dirty. Refer to the user manual for mirror cleaning instructions.
If the housing of the device becomes dirty or dusty, clean it with a soft dry cloth. If necessary, dampen the cloth with isopropyl alcohol. Always unplug the device and remove the battery before cleaning with alcohol.
To ensure proper functioning of the scanner, it should be checked by Topcon customer service on a regular basis within the yearly maintenance and certification service. The service intervals should not exceed one year. Contact your local Topcon Customer Service team for more information.
Warning:
Hand injuries due to spinning mirror
If the scanner is accidentally switched on, the mirrors may start to turn. Before starting any cleaning activity:
- shut-down the laser scanner module and remove the battery pack.
- if using an external power supply, remove the power line. This will prevent the mirror from turning during the cleaning.