Attach the receiver to the survey pole, measure the height, connect accessories, set power to ON, and connect to the network with field software for correction reception.
- Use the 5/8-11 in threaded insert to attach the HiPer XR receiver to the survey pole.
- Make sure that it is correctly attached.
- Measure the height of the receiver from the ground.ADDITIONAL INFORMATION:When you use a fixed-height survey pole, record the measurement reading to enter the antenna height into the software for a vertical height.
- When you use an internal radio modem, attach the applicable radio antenna to the receiver.ADDITIONAL INFORMATION:See the accessories list to identify the correct radio antenna for the frequency range.
- Push and hold the Power button for 2 seconds to set the receiver power to ON.
- Use Topcon field software such as Topcon Field or Pocket 3D to start the software on the field controller and connect to the rover receiver through Bluetooth, USB, or Wi-Fi.
- Configure the receiver for the communication method to receive corrections (UHF radio, LongLink Bluetooth, or cellular modem).