Valve offset and valve gain calibration

MC-Max Dozer Systems requires four valve offsets which must be individually calibrated during initial setup or after hydraulic maintenance.
  • If valve offsets are too low, the cutting edge will not reach on-grade
  • If valve offsets are too high, the cutting edge will move too far and overshoot on-grade.
The valve offset calibration determines the minimum electrical signal required to begin moving the machine’s hydraulic cylinder to return the cutting edge to on-grade.
  • Valve Offset determines the electrical requirement.
  • Valve Gain determines the speed of the cylinder.
Warning: The auto feature must be enabled for the blade to move automatically (in automatic mode) during this procedure. Press the joystick button for auto to enable the feature. Keep your body away from the blade.
  1. Verify the hydraulic settings as recommended by the OEM for 3rd-party control systems.
  2. Refer to the machine settings in the MyTopconNow! application for more information.
  3. Make sure that engine and hydraulic temperatures are in the normal operating range.
  4. Make sure that the hydraulic fluid level is filled to the manufacturer’s specified level.